Health & Medicine

    0.5ml Self-Standing Microtubes with CE Certificate and Steril

    Biologix Corporation
    • Type:General Lab Supplies
    • Material:Plastic
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:Two Years
    • Group:Adult
    • Logo Printing:With Logo Printing

    Base Info

    • Model NO.:81-0054,0056,0153,0203
    • Color:Clear
    • Steril:Yes
    • Autocalvable:Offer
    • Name:Tube
    • Height:30,31,4.5,45.1
    • Standing:Option
    • Transport Package:500 Tubes,Pack, 8 Packs,Case
    • Specification:CE, FDA, ISO9001
    • Trademark:BIOLOGIX
    • Origin:Changzhou City, Jiangsu Province, China
    • HS Code:3101001100
    • Production Capacity:200 Cases,Week

    Description

    Basic Info.

    Model NO. 81-0054/0056/0153/0203 Color Clear Steril Yes Autocalvable Offer Name Tube Height 30/31/4.5/45.1 Standing Option Transport Package 500 Tubes/Pack, 8 Packs/Case Specification CE, FDA, ISO9001 Trademark BIOLOGIX Origin Changzhou City, Jiangsu Province, China HS Code 3101001100 Production Capacity 200 Cases/Week

    Product Description

    Features

    *Ultimate in applications from sample storage in vapor phase liquid nitrogen toboiling applications

    *Polypropylene material makes these screw cap tubes perfect for almost every long term storage application.

    *Superior clarity and phenomenal strength

    *Universal screw threads for use

    *Tubes fit most common rotors

    *Autoclavable to 121°C and freezable to -181°C

     

    Cat #
     

    Volume
     

    Bottom
     

    Color
     

    Sterile
     

    Unit
     

    81-0053
     

    0.5ml
     

    Conical
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0054
     

    0.5ml
     

    Self-Standing
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0153
     

    1.5ml
     

    Conical
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0154
     

    1.5ml
     

    Self-Standing
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0203
     

    2.0ml
     

    Conical
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0204
     

    2.0ml
     

    Self-Standing
     

    Clear
     

    No
     

    500 Tubes/pack, 8 Packs/case
     

    81-0000
     

    Caps
     

    -
     

    Clear
     

    No
     

    500 Caps/pack, 8 Packs/case
     

    81-0001
     

    Caps
     

    -
     

    Pink
     

    No
     

    500 Caps/pack, 8 Packs/case
     

    81-0002
     

    Caps
     

    -
     

    Green
     

    No
     

    500 Caps/pack, 8 Packs/case
     

    81-0003
     

    Caps
     

    -
     

    Blue
     

    No
     

    500 Caps/pack, 8 Packs/case
     

    81-0004
     

    Caps
     

    -
     

    Yellow
     

    No
     

    500 Caps/pack, 8 Packs/case
     

    81-0005
     

    Caps
     

    -
     

    Assorted
     

    NO
     

    500 Caps/pack, 8 Packs/case
     
    0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril0.5ml Self-Standing Microtubes with CE Certificate and Steril
    1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    1. What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     
    主站蜘蛛池模板: 四会市| 教育| 遵化市| 都兰县| 赤壁市| 谷城县| 千阳县| 汕头市| 商南县| 中西区| 剑阁县| 中宁县| 双鸭山市| 内江市| 靖西县| 丹巴县| 乌兰县| 舟曲县| 梓潼县| 三亚市| 长泰县| 克东县| 包头市| 潼关县| 贵州省| 明光市| 邯郸县| 瑞丽市| 集安市| 昂仁县| 桦南县| 镇巴县| 朝阳县| 宁南县| 东丽区| 肥东县| 边坝县| 景谷| 宜兴市| 卫辉市| 洪江市|