    Tace Surgery Niti Wire Core Medical

    Suzhou Innomed Medical Device Co., Ltd.
    • Type:Surgical Supplies Materials
    • Material:Nickeltitanium Wire Core
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:Two Years
    • Group:Adult
    • Logo Printing:With Logo Printing

    Base Info

    • Model NO.:Inno-Pathwire
    • Certification:CE,ISO13485
    • Application:Ptca,Pta
    • Transport Package:Cardboard Box
    • Specification:Full Specifications
    • Trademark:Inno-Pathwire
    • Origin:Suzhou China
    • HS Code:9018909919
    • Production Capacity:50000,Y

    Description

    OD(mm)L2(cm)IW-14-300-STS300±1543±23±0.15≤0.36IW-14-300-MDS300±1543±23±0.15≤0.36IW-14-300-EXS300±1543±23±0.15≤0.36IW-18-100-MDS100±530±21.5±0.15≤0.46IW-18-150-MDS150±7.530±21.5±0.15≤0.46IW-18-200-MDS200±1030±23±0.15≤0.46IW-18-300-EXS300±1510±23±0.15≤0.46
    Directions for use
    1. Carefully insert the guidewire through the guidewire lumen hub of the interventional device.
    2. Advance the guidewire until its tip is just proximal to the interventional device tip.
    3. If using a guiding catheter, engage the guiding catheter and insert the interventional device/ guidewire assembly through the hemostatic valve. Advance the system through the guiding catheter until it is just proximal to the tip of the guiding catheter.
    4. Tighten the hemostatic valve to create a seal around the interventional device. Ensure intentional guidewire movement is still permitted.
    5. Attach the torque device to the guidewire, if desired.
    6. Under fluoroscopy, advance the guidewire out of the interventional device while securing the interventional device in place. Use the torque device to steer the guidewire across the lesion.
    7. Secure the guidewire in place while tracking the interventional device over it and to the target lesion.
    8. If a different tip configuration or guidewire is indicated, carefully remove the guidewire while observing guidewire movement under fluoroscopy.
    9. Reshape the guidewire tip according to standard practice or prepare another guidewire to be used.
    10. Reinsert the guidewire following Steps 1 through 7 of this section.