Health & Medicine

    1 Inch Scan-Ready Cryoboxes Filled with 2D Barcoded Cryo Vial

    Biologix Corporation
    • Type:PE Material
    • Material:Plastic
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:Two Years
    • Group:Adult
    • Logo Printing:With Logo Printing

    Base Info

    • Model NO.:89-3050,89-3051,89-3052,
    • Color:White, Pink, Green, Blue, Yellow, Purple
    • Brand:Biologix
    • Standing:Yes
    • Bottom Code:Offer
    • Steril:Yes
    • Package:Rack and Bulk
    • Transport Package:1200 Vials+12 Boxes,Case
    • Specification:CE, FDA, ISO9001
    • Trademark:BIOLOGIX
    • Origin:Changzhou City, Jiangsu Province, China
    • HS Code:3101001100
    • Production Capacity:200 Cases,Week

    Description

    CryoKING® ComboScan-Ready Cryoboxes filled with 2D barcoded cryovials89-30500.5ml Vials
    +1in BoxWhite




    * The 2D coded cryogenic vials have been fit in the boxes
    * For automatic management
    * Sterile
    100 Vials+1 Box/Bag,
    6 Bags/Pack,
    2 Packs/Case,
    1200 Vials+
    12 Boxes/Case
     89-3051Pink89-3052Green89-3053Blue89-3054Yellow89-3055Purple89-31001.0ml Vials
    +2in BoxWhite89-3101Pink89-3102Green89-3103Blue89-3104Yellow89-3105Purple89-31501.5ml Vials
    +2in BoxWhite89-3151Pink89-3152Green89-3153Blue89-3154Yellow89-3155Purple1 Inch Scan-Ready Cryoboxes Filled with 2D Barcoded Cryo Vial1 Inch Scan-Ready Cryoboxes Filled with 2D Barcoded Cryo Vial1 Inch Scan-Ready Cryoboxes Filled with 2D Barcoded Cryo Vial1 Inch Scan-Ready Cryoboxes Filled with 2D Barcoded Cryo Vial
    1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    1. What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     
    主站蜘蛛池模板: 保德县| 德令哈市| 永清县| 紫金县| 汉川市| 兴和县| 仁怀市| 土默特右旗| 手游| 松潘县| 靖边县| 迁西县| 邹平县| 闽侯县| 黄冈市| 宜昌市| 即墨市| 南丰县| 遂昌县| 龙岩市| 阜新市| 聂荣县| 湛江市| 乌兰浩特市| 长汀县| 武安市| 雷山县| 治县。| 运城市| 景谷| 溆浦县| 湘西| 麻城市| 凯里市| 普陀区| 巩义市| 武汉市| 宣恩县| 鄯善县| 苗栗市| 绥芬河市|