    Skin Surface Temperature Probe Single Use Probe

    Hefei Jingpu Sensor Technology Co., Ltd.
    • Type:Surgical Supplies Materials
    • Material:PVC
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:One Year
    • Group:Adult
    • Logo Printing:Without Logo Printing

    Base Info

    • Model NO.:JP403
    • Transport Package:Neutral Packing
    • Specification:Ф 5.8mm
    • Trademark:J. P. Sensor
    • Origin:Hefei, Anhui, China
    • HS Code:9025199090
    • Production Capacity:50000PCS,Year

    Description

    Operating Temp. Range: -40 to +150ºC Type150±3ºCOperating Temp. Range: -40 to +125ºC Type125±3ºCMeasurement at 24±2 hours after test condition.Temperature Cycling- Resistance (R25) change should be less than ±5%.
    - B-constant(B25/50) change should be less than ±2%.
    - No visible damagePerform 1000 cycles according to the four heat treatments listed in the following table.
    Step1234
    Temp.(deg.C)-55+0/-3Room Temp.125+3/-0Room Temp.
    Time (min.)15±3115±31
    Measurement at 24±2 hours after test condition.Moisture Resistance- Resistance(R25) change should be less than ±5%.
    - B-constant(B25/50) change should be less than ±2%.
    - No visible damage.Apply the 24-hour heat (25 to 65ºC) and humidity (80 to 98%) treatment shown below, 10 consecutive times. Measurement at 24±2 hours after test condition.Biased Humidity- Resistance (R25) change should be less than ±10%
    - B-constant(B25/50) change should be less than ±2%
    - No visible damage.85±2ºC, 85%RH in air for 1000 hours with Permissive Operating Current. Measurement at 24±2 hours after test conditionsOperational Life- Resistance(R25) change should be less than ±5%
    - B-constant (B25/50) change should be less than ±2%
    - No visible damage85±3ºC in air for 1000 hours with Permissive Operating Current. Measurement at 24±2 hours after test conditionsExternal VisualNo defects of abnormalitiesVisual Inspection.Physical DimensionWithin the specified dimensionsUsing calipers
    Skin Surface Temperature Probe Single Use ProbeAdhesive foam evaluated by bio-compatibility can be fixed on measuring position, it is with no irritation to the skin and with better comfort. The foam reflector can effectively insulate ambient temperature and radiant light to ensure normal operation.

    FAQ:
    Q: Can you show the match behind conversion from % tolerance to actual temperature tolerance?
    A: To determine the temperature accuracy simply divide the total deviation (resistance tolerance) by the Alpha for the temperature of interest.

    Q: Does the thermistor accuracy specifications include any long term resistance change over time (resistance stability)?
    A: No, the accuracy is specified as the accuracy of the sensor shipped. We have no control of the application or the environmental conditions the sensor will be subjected to in the field.

    Q: What does % mean when talking about temperature accuracy?
    A: Sensor's accuracy can be specified as resistance tolerance or to a temperature accuracy at either a single point at ... over a span.

    Q: What advice can you give for glueing a thermistor to a metallic surface have?
    A: Adhesives are used in many applications to attach a thermistor for surface temperature measurement. A thermally conductive adhesive, usually epoxy, will give optimal results.


     