Health & Medicine

    3ml Sterilized Transfer Pipets with Gamma Strile

    Biologix Corporation
    • Type:General Lab Supplies
    • Material:PE Material
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:Two Years
    • Group:Adult
    • Logo Printing:With Logo Printing

    Base Info

    • Model NO.:30-0138A1
    • Length:162.0mm
    • Package:Individually
    • Sterile:Gamma
    • Graduation:Molded Graduation
    • Transport Package:500,Pack, 10 Packs,Case
    • Specification:CE, FDA, ISO9001
    • Trademark:BIOLOGIX
    • Origin:Changzhou City, Jiangsu Province, China
    • Production Capacity:200 Cases,Week

    Description

    Basic Info.

    Model NO. 30-0138A1 Length 162.0mm Package Individually Sterile Gamma Graduation Molded Graduation Transport Package 500/Pack, 10 Packs/Case Specification CE, FDA, ISO9001 Trademark BIOLOGIX Origin Changzhou City, Jiangsu Province, China Production Capacity 200 Cases/Week

    Product Description

    Features
    *Polyethylene pipettes will not shatter or break
    *Good alternative to pasture pipettes and rubber bulbs
    *Perfect products for quick, safe transfer of fluid
    *Long flexible stem can be bent to draw liquid from
    Narrow or small volume tubes into the bulb
    *Uniform drop size
    *Available with gamma irradiation sterilized or non-sterilized
    *Integral, self-contained pipettes eliminate the problems of
    Attaching rubber bulbs and suction devices or changing
    Pipette tips
    *Good thickness distribution guarantees suction force


    Packaging
    *Individually package in easy-open paper/plastic pouch is available
    *Also available with bulk package in easy-open plastic bags

    Pipet Design
    *Available with 2 capacities of 1.0 and 3.0ml
    *Molded graduations
    *100% inert for accurate sampling
    *Transparent wall permits easy viewing of pipette contents

    Cat#
     

    Package
     

    Length
     

    Graduated to
     

    Sterile
     

    Unit
     

    30-0135
     

    Bulk
     

    160.0mm
     

    1ml
     

    No
     

    500/pack,10packs/case
     

    30-0135A1
     

    Individually

    Wrapped
     

    160.0mm
     

    1ml
     

    Yes
     

    500/pack,10packs/case
     
          

    30-0138
     

    Bulk
     

    160.0mm
     

    3ml
     

    No
     

    500/pack,10packs/case
     

    30-0138A1
     

    Individually

    Wrapped
     

    160.0mm
     

    3ml
     

    Yes
     

    500/pack,10packs/case
     
    3ml Sterilized Transfer Pipets with Gamma Strile3ml Sterilized Transfer Pipets with Gamma Strile3ml Sterilized Transfer Pipets with Gamma Strile3ml Sterilized Transfer Pipets with Gamma Strile
    1. What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
    1. What are autoclaving guidelines of plastics?
    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

     
    主站蜘蛛池模板: 英山县| 江阴市| 长葛市| 轮台县| 清水县| 洛浦县| 襄樊市| 津南区| 海门市| 桂平市| 衡南县| 会理县| 曲水县| 平山县| 温宿县| 连平县| 凭祥市| 上栗县| 海南省| 罗田县| 新丰县| 固阳县| 隆尧县| 中卫市| 徐汇区| 格尔木市| 西畴县| 长寿区| 望江县| 双流县| 曲周县| 仁怀市| 滨州市| 苗栗市| 靖江市| 淮安市| 河源市| 措勤县| 屏东县| 元氏县| 科技|