Health & Medicine

    Highly Specific Bilirubin Absorption Column

    Guangdong Baihe Medical Technology Co., Ltd.
    • Type:Vacuum Blood Tube & Blood Bag
    • Material:Plastic
    • Ethylene Oxide Sterilization:Ethylene Oxide Sterilization
    • Quality Guarantee Period:Three Years
    • Group:Adult
    • Logo Printing:With Logo Printing

    Base Info

    • Model NO.:DX350
    • Transport Package:Carton
    • Specification:49*41.5*22cm
    • Origin:China
    • HS Code:9013809000
    • Production Capacity:50000000PCS,Year

    Description

    Basic Info.

    Model NO. DX350 Transport Package Carton Specification 49*41.5*22cm Origin China HS Code 9013809000 Production Capacity 50000000PCS/Year

    Product Description


    HIGHLY SPECIFIC BILIRUBIN ABSORPTION COLUMN INFORMATION
    DX Series bilirubin adsorption column is designed for treatment of fulminant hepatitis, post-operative liver failure, primary biliary cirrhosis, hyperbilirubinemia and Bile acid syndrome. The adsorption of bilirubin and bile acid from plasma and is an effective and safe approach for hemopurification of the patients who have hepatopathy such as fulminant hepatitis, post-surgery hepatic failure, primary biliary cirrhosis and hyperbilirubinemia.
     

    Treatment Sketch

    After separated, the plasma is purified by passing through DX Series bilirubin absorption column and subsequently return back to human body

    Plasma Bilirubin Absorption

    Highly Specific Bilirubin Absorption Column                                                                            Treatment sketch - Plasma Bilirubin Absorption
    Double Plasma Molecule Absorption System (DPMAS)
    Highly Specific Bilirubin Absorption Column
    Absorption Mechanism
    The function of bilirubin adsorption is decided by electrostatic interaction between the negative charge of the carboxyl group of bilirubin and the positive charge of quaternary ammonium salt of the anion exchange resin.
    Highly Specific Bilirubin Absorption Column 

    Vitro Test Result

    Absorption rate in plasma (in vitro).

    Highly Specific Bilirubin Absorption Column
    Vitro Test Condition:
    Absorption column: one pass (1/350) Sample: plasma 2.4L (Equivalent volume) Flow rate: 20mL/min(Equivalent rate)
     